Dispensing / Sampling Booth (RLAF)

Dispensing / Sampling Booth (RLAF)

APPLICATIONS

Industry / Area Application Purpose / Benefit
Pharmaceuticals Sampling and weighing of APIs and excipients Prevents cross-contamination and ensures clean handling
Chemicals Dispensing of hazardous or fine chemical powders Protects operators from inhalation and maintains workplace safety
Food & Beverages Handling of food-grade powders and additives Maintains hygiene and prevents contamination
Biotechnology & R&D Labs Media preparation, reagent handling, and powder weighing Ensures a sterile and controlled environment
Cosmetics & Nutraceuticals Dispensing of raw cosmetic powders or herbal extracts Ensures GMP compliance and a safe, dust-free environment
Powder Processing Units Weighing and transferring of bulk powders Provides dust control and protects both operator and product

For More Technical Information Download The Catalogue

KEY FEATURES

Controlled Environment

  • Provides a clean, dust-free, and controlled space for weighing, dispensing, and sampling of powders and granules.
  • Ergonomic Design Stainless steel (SS 304/316) construction with smooth, rounded corners for easy cleaning and GMP compliance. (Optional)

 

HEPA Filtration System

  • Equipped with HEPA filters (H13/H14 grade) for rapping fine airborne particles and preventing contamination

 

Laminar Airflow

  • Vertical or downward laminar airflow ensures continuous flushing of airborne dust away from the operator’s breathing zone

 

Product & Environment Protection

  • Ensures cross-contamination-free operations. Maintains ISO Class 5–8 clean air in the working zone depending on design.

 

Airflow Monitoring

  • Equipped with airflow indicators/pressure gauges for real- time monitoring.

 

Illumination

  • Energy-efficient LED/fluorescent lights with proper lux levels inside the working zone.

 

Noise & Vibration Control

  • Designed for low noise (<65 dB) and minimal vibration for comfortable long-duration use.

 

Safety Interlocks

  • Sometimes provided with UV light interlocks, differential pressure alarms, and safety shutdown systems.

 

Compliance

  • Meets GMP, GLP, and regulatory standards of pharmaceutical, food, and chemical industries.

 

AIRFLOW & FILTRATION
  • Type of Airflow: Vertical Laminar Air Flow with reverse flow at operator level
  • Air Velocity: 0.45 ± 0.05 m/s (across work zone)
  • Primary Filter: Pre-filter (10 μm, 90% efficiency)
  • Secondary Filter: Fine filter (5 μm, 95% efficiency)
  • Final Filter: HEPA Filter H13/H14 (0.3 μm, 99.97% efficiency)
  • Air Recirculation: Vertical recirculation
  • Air Cleanliness: ISO Class 5 (as per ISO 14644-1)